Engtips.

Efficiency (measured in stiffness or strength per unit of weight) is not highest with compact sections - it is actually quite the opposite. Class 3 sections, for example, rarely require transverse or longitudinal stiffeners, but the larger web depth acquired with them far offsets any issues relating to elastic section capacity or local buckling.

Engtips. Things To Know About Engtips.

Want to know the do's and don'ts of Eng-Tips? Read FAQ731-376: Eng-Tips.com Forum Policies. English not your native language? Looking for some help in getting your question across to others or understanding their answers? Go to forum1529: Translation Assistance for Engineers.Ignition, Combustion and Detonation engineering. Laser engineering. Mechanical Seal engineering. Mechanical Acoustics/Vibration engineering. Optical systems engineering. Pipelines, Piping and Fluid Mechanics engineering. Pump engineering. Storage tank engineering. Valve engineering.Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …

Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other users. The targeted audience of Eng-Tips is engineering professionals. Its total height is 140 mm, where height of steel deck is 60 mm and height of concrete above slabs is 80 mm, so I've put that both membrane and bending thicknesses are 140mm = 0,14m. As a material I've chosen concrete C30/37 defined in Materials (I'll attach my model in SAP2000 at the end of the post). This concrete's Weight per Unit Volume is ...

It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …Ayurveda. Unani. Homeopathy. Cowpathy. You’ve heard of ayurveda, the traditional Indian medical science. So have you about Unani, the Perso-Arabic healing science. Then there is ho...

The first one is applying point load on the flange and the Beff that can be used for capacity calculation. Mu = P x a. S = beff x t^2 / 6. Mc = phi x fy x S. Second image is the scenario with stiffener added. How do we calculate the capacity for such cases? Thanks.PE Structural CBT April 2024. I am beginning to study for the the new PE Structural (SE) exam that is a computer based test (CBT) beginning in April 2024. All prep courses I have seen online are for the existing SE exam. I am wondering if anyone else is studying for the new format SE exam and how you are going about studying.To ask an engineering question please visit our forum site at Eng-Tips. Browse our archive of questions and answers below or to access our old forum database of over 10000 questions and answers please visit the old Ask@ forum. Forums; Search; Unanswered; Active Topics; Engineering Questions and Answers: Forums: Topics: Replies: Last Post: …Fluid Power engineering. (8474 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search.

Petroleum engineering general discussion. (13755 members) forum481 - Professional forum and technical support for engineers for Petroleum engineering general discussion. Includes problem solving collaboration tools.

Pre-calculatoin of torispherical heads acc. to ASME BPVC VIII Div.2 2023 (4.3.6.1) leads to a thinner wall than a simple cylindrical shell (4.3.3.1). Also, the

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.)1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the …Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools.The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …

Mechanical engineering general discussion. (88334 members) forum404 - Professional forum and technical support for engineers for Mechanical engineering general discussion. Includes problem solving collaboration tools. 1) Perforated. There are code restrictions on why you can use this. It is generally less expensive than the FTAO (Force Transfer Around Openings) method because it does not require you to use straps around all the openings. 2) FTAO: To me, this method is merely a "rational" method.ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members …Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …A restrained retaining wall with fixity between the footing and the stem is indeterminate. As the at-rest pressure goes to work on the stem, it's obvious that the horizontal reaction at the top of the wall will increase. If the stem and stem-footing joint are very stiff, they will significantly limit stem deflection and rotation of the stem ...smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.

11 Oct 10 01:39. In CMAA 74, paragraph 3.3.2.4.2 states: The localized stresses due to local bending effects imposed by wheel loads calculated at points 0 and 1 are to be combined with the stresses due to the Case 2 loading specified in paragraph 3.3.2.3.2 of this specification. However, it does not explicitly state how they should …

Dynamic Cone Penetrometer (DCP) is a very poor tool for evaluating modulus of subgrade reaction (k) or modulus of rupture (M R).In my opinion, you would be better off guessing - at least then you would be applying your judgement to the problem.May 1, 2017 · Fluid Power engineering. (8465 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search. DASSAULT: CATIA products. (15414 members) forum560 - Professional forum and technical support for engineers for DASSAULT: CATIA products. Includes problem solving collaboration tools. Forum. Search.But, I expand on them a little: 1) Handbook of Steel Connection Design and Details by Akbar Tamboli. 2) The Following AISC design guidess: a) DG1: Base Plates. b) DGs 4 & 16 for bolted end plate moment connections. c) DGs 12 & 13 for retrofit of existing moment connections and stiffeners for moment … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... *Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home; Forums; Structural Engineers; Activities; Welding, Bonding & Fastener …As we lose the stable structure we’re used to, many of us are now experiencing symptoms of burnout. How can we overcome it? Humans are creatures of habit. We function best and feel...Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange.The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...Shear walls3. I was reading reinforced concrete mechanics by MacGregor about shear walls. The book says that a possible solution to decrease foundation size is to " Attach the base of the wall to the ground-floor diaphragm and basement floor to provide a horizontal force couple to react to the moment at the …

thread404-515636. Dynamo2000 (Mechanical) (OP) 19 Jan 24 21:00. Very recently in the news was an invention called the Holo Tile Floor created by Disney's National Inventors Hall of Fame member Lanny Smoot. This creation allows the user to "walk" in any direction without moving anywhere! The floor shifts to compensate for the user's leg …

Construction Process2. Construction Process. 2. As a new junior engineer without much construction experience, I wanted to ask whether there is a trustworthy resource which goes into a detailed narrative of the construction process, encompassing from the beginning paperwork, typical teams making up a project, …

Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools. 22 hours ago · Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... MotorCity (Structural) 16 Sep 04 09:48. KarlIt, I would suggest consulting the goal manufacturer to obtain the design loads. The support system will vary among models and manufacturers. This type of loading is not governed by any particular code as it is not a building or structure. That has been my approach for the gymnasium designs in the ... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... In B31.3, there is reference to hardness testing in accordance with 333.1.7., see below. 331.1.7 Hardness Tests. Hardness tests of production. welds and of hot bent and hot formed piping are. intended to verify satisfactory heat treatment. The hardness. limit applies to the weld and to the heat affected.We calculate the rms value of fault current (If) at the onset of it (t=0sec), using subtransient values of reactances for the sources and taking no account of the dc component. Then, the make current is : 2.55*If. and break current is : 1.255*If. with dc component included in both cases. dpc (Electrical) 23 Jan 02 …All the handrails have to meet the requirements. Loading one side vs the other side is really irrelevant to the handrails and its connections. If there is some loading you are concerned about the in the elements supporting the handrails you might want to consider the loading on each of them simultaneously or perhaps just one side.Deflections under seismic loading - Part 2. It's my understanding that 4.1.8.11.3) d) v) allows us to use a larger period specifically to check seismic deflections. This means I'll have a different base shear than my regular elastic analysis, so I always run a distinct case anyways. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Financial planners explain how to balance stocks and bonds in your 401(k). Your age plays a major factor. By clicking "TRY IT", I agree to receive newsletters and promotions from M...

DASSAULT: CATIA products. (15414 members) forum560 - Professional forum and technical support for engineers for DASSAULT: CATIA products. Includes problem solving collaboration tools. Forum. Search.Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other …Steel Stair Seismic Design. I have posted a couple of threads regarding this subject in the past, but I would like to post a more thourough question regarding providing seismic design on steel stairs. I have a particular project which is in the Missouri area and is governed by the 2006 IBC and ASCE 7-05. I have …Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …Instagram:https://instagram. is fidium fiber downlike some batteries and baseball teams nyt crossword cluechampions league winners wikimrscallace onlyfans Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools. urgent care express ankenyspectrum outage middleton wi Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent … souvenir t shirts near me Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools. A common rule for situations like this is extend the depth of calculation to the point where the added pressure is 10% of existing pressure. the total extent of settlement is informed by soil modulus and the consolidation index (Cc) or consolidation ratio (Cec). If the clay is overconsolidated, then it'd be Cr, or Cer. Activities. Civil/Environmental engineering general discussion. Climate Change Engineering Solutions. Earthwork/grading engineering. Soil/Groundwater environmental engineering. Storm/Flood engineering. Surveying & Geomatics. Traffic Engineering. Waste disposal & treatment.