Lennox nomenclature model number.

We have done the research to provide you with the details about the tonnage of a Goodman air conditioner. You can determine the tonnage of your Goodman air conditioning by dividing the BTU by 12,000. If the information about the BTU is not available, you can check the model number. You will find 0 and two-digit even numbers ranging …

Lennox nomenclature model number. Things To Know About Lennox nomenclature model number.

The Goodman model number can be found on a data tag located on the rating plate of your air conditioner, heat pump or furnace. Look at a slightly above the refrigerant valves on the back side of the A/C unit as show on the picture below. The Goodman model number is made up of a series of letters and numbers that tell what kind of furnace it is.FEATURES − LCA MODELS Item LCA156H LCA180 LCA210 LCA240 LCA300S Approvals E.T.L. and C.G.A. listed, efficiency rating verified by C,.S.A., componentsMODEL NUMBER IDENTIFICATION Minor Revision Number HS Y Unit Type HS = High Side Condensing Unit 036 1 Cooling Capacity Tons (kW) 018 = 1.5 (5.3) 024 = 2 (7.0) ... NOTE − Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. MODEL NUMBER IDENTIFICATION. ELA 6 to 20 Ton Air Handlers / Page 2 180-240 Models 072-090-120-150 Models ... • Lennox fabricated coil is constructed of precisely MODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual units ...

Model Number KGB092S4B KGB092S4M KGA092H4B KGA092H4M Efficiency Type Standard Standard High High Blower Type CAV (Constant Air Volume) MSAV® (Multi-Stage Air Volume) CAV (Constant Air Volume) MSAV® (Multi-Stage Air Volume) Cooling Performance Gross Cooling Capacity - Btuh 87,800 87,800 93,000 93,000 1 Net Cooling Capacity - Btuh 86,000 86,000 ...KCa. Landmark®Rooftop Units. Standard Efficiency - 60 HZ. 3 to 7.5 Tons Net Cooling Capacity - 36,200 to 90,000 Btuh Optional Electric Heat - 7.5 to 30 kW. MODEL NUMBER IDENTIFICATION K C A 060 S 4 B N 1 Y. Brand/Family K = Landmark®Product Line Unit Type C = Packaged Electric Cooling w/ optional Electric Heat Major Design Sequence A = 1st ...

Model No. 2SCU13LC136T 2SCU13LC148T 2SCU13LC160T Nominal Tonnage 3 4 5 Connections (sweat) Liquid line o.d. - in. 3/8 3/8 3/8 Suction line o.d. - in. 7/8 7/8 7/8 1 Refrigerant charge field supplied (R-22) 5 lbs. 12 oz. 7 lbs. 8 oz. 10 lbs. 0 oz. Outdoor Coil Tube diameter - in. 5/16 5/16 5/16 Number of rows 1 1 2 Fins per inch 26 22 22 Outdoor Fan

If you're an HVAC contractor or technician interested in a free test procedure describing simple testing you can do on a sales visit, contact Doc at [email protected] or call him at 800-633-7058. Go to NCI's website at nationalcomfortinstitute.com for free information, articles, and downloads. Download.The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1PHS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics. GCS16-090-350-2YGCS16 is the Series, 090 is the Cooling Capacity, 350 ...Model/Part Number CB29M-46-4P Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) Product Voltage 208/230v 1ph 60 hz Gross Weight. 162 LB. Family. CB29M . Cooling Capacity. 3.5 Ton Cooling . Hertz ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...NOTE - Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. ... Model Number 26HWC123 38HWC123 38HWC183 51HWC183 38HWC243 51HWC243 51HWC303 Input - kW (Btuh) 7.6 (26 000) 11.1 (38 000) 14.9 (51 000) 11.1 (38 000) 14.9 …History Of The County Of Lennox And Addington NOMENCLATURE, AIRCRAFT AIR CONDITIONING EQUIPMENT Charlotte Lennox The Epilepsies Antique Electric Waffle Irons 1900-1960 Top Secret Files Lennox Model Number Nomenclature Downloaded from jmsseniorliving.com by guest DANIELA JUNE International Code of Nomenclature for Cultivated Plants Zondervan

2) Look for a sheet taped to the front of the air handler (indoor unit), where the HVAC contractor has listed the performance data for the system. 3) Some manufacturers encode the SEER rating in the beginning of the model number on the data plate of the condenser. For example, the "XC21" at the beginning of the model number of the Lennox ...

MODEL NUMBER IDENTIFICATION. XP14 - 2 to 5 Ton Heat Pump / Page 2 ... NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. XP14 - 2 to 5 Ton Heat Pump / Page 4 REFRIGERATION SYSTEM (continued) High Pressure Switch

TSA120S4S. T-Class™ Large Split Systems 6-20 Ton Units 60 hz and 50 hz. Reliable, cost-effective and service-friendly split systems. Standard Efficiency. Efficiency. Up to 11.7 EER. Scroll compressor (s) provides smooth, efficient and quiet operation. Outdoor coil fan moves large volumes of air uniformly through entire condenser coil for high ...lennox industries model number chart air handling (cb 31 w-41-1p) cb31mv41- p voltage 1 phase -60 ez g 3 phase - 60 minor revision number ca?acity sae as cond- units model description cb = col-blower m = multi-position v = variable spf-ee modetjsÉrles 29 = standard 30 efficiency 31 = vanable speed 17 = conmercial 1 31 46 65 95 = 135 = 10 tonMODEL NUMBER IDENTIFICATION RESIDENTIAL PRODUCT SPECIFICATIONS Ratings Revision Level (NOTE - 018-024-030-036-042 models only) Regional Standards ... NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPLICATIONS • 1.5 through 5 tons2 to 5 Ton (7.0 to 17.6 kW) Rooftop Installation with Horizontal Economizer Rooftop Installation With Economizer and Combination Supply and Return Air System. GCS20 Basic Unit. MODEL NUMBER IDENTIFICATION. 120. Minor Revision Number. GCS Y. Unit Type GCS = Packaged Gas Heat/Cooling Unit 0361. Cooling Capacity Tons (kW) 024 = 2 (7.0) 030 = 2.5 ...Model No. CHA16024 CHA16030 CHA16−036 CHA16−048 CHA16−060 Ceiling Diffusers − Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed StepDown − double deflec tion louvers RTD9−65 − 67 lbs. (30 kg) flow),The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics. GCS16-090-350-2Y GCS16 is the Series, 090 is the Cooling …model number lch/lgh 120h4b lch/lgh 120h4m lch/lgh 150h4b lch/lgh 150h4m lch/lgh 156h4b lch/lgh 156h4m/v lch/lgh 180h4b lch/lgh 180h4m/v lch/lgh 210h4b lch/lgh 210h4m lch/lgh 240h4b lch/lgh 240h4m/v lch/lgh 300s4b lch/lgh 300s4m blower type cav msav cav msav cav msav/vav cav msav/vav cav msav cav msav/vav cav msav net cooling capacity (btuh ...

MODEL NUMBER IDENTIFICATION 1 Indoor coils with the same letter designation will physically match the furnace. AFUE 80 = 80% Low NO x X = Units meet California Nitrogen Oxides Standard (40 ng/J) Cabinet Width A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. PRODUCT SPECIFICATIONS ML180UH UPFLOW/HORIZONTAL GAS FURNACESCreated Date: 5/14/2002 3:16:17 PMMODEL NUMBER IDENTIFICATION Minor Revision Number HS Y Unit Type HS = High Side Condensing Unit 036 1 Cooling Capacity Tons (kW) 018 = 1.5 (5.3) 024 = 2 (7.0) ... NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.The date of production/manufacture or age of Lennox brand HVAC equipment can be determined from the ten character serial number located on the rating …Model/Part Number KCA092S4BN Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255146286 Product Voltage 460v 3ph 60 hz Size/Dimensions 48x60.5x101.5 Horsepower. 2 . Blower Type or Drive # ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Approvals — Condensing units have been tested in the Lennox Research Laboratory environmental test room and rated in accordance with ARI Standard 210/240-94. In addition, units have been sound rated in the Lennox reverberant sound test room in accordance with test conditions in included in ARI Standard 270-95. Condensing units

tech.lennoxintl.com Model/Part # : CB29M-46-4P. Product Unavailable Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart ... I DO NOT have a Lennox Customer Number.

On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.MODEL NUMBER IDENTIFICATION. LGA060 H 2 B S 1 Y. Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family L = L Series Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − Tons 036 = 3 Tons 042 = 3.5 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons Cooling ...First letter: The model number starts with 4. This number represents the type of refrigerant the unit uses. 2 stands for R-22 and 4 stands for R410A. Second letter. T stands for Trane. The next 3 letter represents the product type. W stands for split heat pump and T stands for split cooling.Efficient and Affordable. The ML17XP1 offers energy efficiencies of up to 18.60 SEER and 10.60 HSPF, equivalent to 17.00 SEER2 and 8.50 HSPF2, delivering comfort and energy savings at a more affordable price.Subject: Image Created Date: 7/1/2008 3:32:44 PMlennox industries model number chart air handling (cb 31 w-41-1p) cb31mv41- p voltage 1 phase -60 ez g 3 phase - 60 minor revision number ca?acity sae as cond- units model description cb = col-blower m = multi-position v = variable spf-ee modetjsÉrles 29 = standard 30 efficiency 31 = vanable speed 17 = conmercial 1 31 46 65 95 = 135 = 10 tonThe CHX35 family of coils are designed with aluminum tube construction which provides great heat transfer and additional resistance to environmental contaminants. Durable components, such as corrosion-resistant casing and drain pans, help guard against unexpected service calls. CHX35-42B-6F-1 coil is built to high standards and is backed by ...

The 10ACC is a residential split-system condensing. unit available in sizes ranging from 1-1/2 to 5 tons. Con-. densing coil size, circuiting and air volume result in a. minimum SEER rating of 10.0. The series is designed. for use with an expansion valve or RFCIV system in the. indoor unit.

Solar. SunSource® Commercial Energy System5. Factory. Field. Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX ©2019 Lennox Industries, Inc. (14G47) 2/19 PC92164. 92164_energence_RTU_qr_guide.indd 2. 3/4/19 9:30 AM.

These new regulations mandated higher minimum SEER ratings, with different standards for different parts of the country. North. Split Systems-. Air Conditioners: 13 SEER. Heat Pumps:14 SEER, 8.2 HSPF. Packaged Units-. Air Conditioners: 14 SEER. Heat Pumps:14 SEER, 8.0 HSPF. Southwest.HVAC BRAND MODEL NUMBER NOMENCLATURE. Select one of the drop-down lists below. that corresponds to the FIRST letter. of your HVAC brand name. Then make your selection from the list. HVAC - A. HVAC - B. HVAC - C. HVAC - D. HVAC - E. HVAC - F. HVAC - G. HVAC - H. HVAC - I. HVAC- J. HVAC - K. HVAC - L. HVAC - M. HVAC - N. HVAC - O. HVAC - P. HVAC - Q.Model/Part Number KGB048S4BM Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255149262 Product Voltage 208/230v 3ph 60 hz Horsepower. 1 HP . Blower Type or Drive # Belt Drive-CAV . SEER. 14 ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...2013 Lennox Industries Inc. Dallas, Texas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE WARNING The State of California has determined that this product ... Model Number A B C XP14-018-230 31 (787) 30-1/2 (775) 35 (889) XP14-024-230 39 (991) XP14-030-230 39 (991) XP14-036-230 35 (889)The second two numbers of the serial number are the year of manufacture, so the data plate for the Lennox furnace shown below indicates it was produced in 2013. To determine other key specs of your HVAC system, see one of these other blog posts: • How do I determine the age of my air conditioner?Lennox model numbers 14= 1 ton 21= 1-1/2 ton 26= 2 ton 31= 2-1/2 ton 41= 3 ton 46= 3-1/2 ton 51= 4 ton 65= 5 ton So, your unit is a two ton model. The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are …Merit® Series. 14HPX Heat Pump. Economical, environmentally responsible home cooling and heating. The temperature always feels just right inside with the budget friendly 14HPX-024-230. Precision engineered with quality components, this heat pump allows customers to enjoy exceptional comfort, without the worry of high utility bills.Model/Part Number KGB060S4B Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255148906 Product Voltage 208/230v 1ph 60 hz Horsepower. 1.5 . SEER. 14 . Heat. 65 Single . Return Opening Horizontal ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Lennox model number nomenclature - InterNACHI®️ Forum Jul 23, 2016 · Lennox model number nomenclature Specific Inspection Topics Inspecting HVAC Systems sfetty (Dave Fetty, CMI) July 23, 2016, 8:15pm #1 This is a link to a pdf of the Lennox HVAC equipment model number nomenclaturesLennox model number nomenclature. Specific Inspection Topics. Inspecting HVAC Systems. sfetty (Dave Fetty, CMI) July 24, 2016, 4:21pm 6. cbottger: It will Sammy:p Lennox has always been one of the hardest to decipher. Sammy, my brother goes by that name. show post in topic. Home ; Categories ; FAQ/Guidelines ...The ML14XC1 comes with a 5-year limited warranty on the compressor and all remaining covered components.**. *The cooling efficiency rating for air conditioners is Seasonal Energy Efficiency Ratio, or SEER. The higher the SEER, the better the energy performance, and the more you save. ** Covered components may be eligible to receive a 10-year ...Model/Part # : CB29M-46-4P. Product Unavailable Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart ... I DO NOT have a Lennox Customer Number.

Trane Model Number Nomenclature. OK, here is the breakdown of the Trane model lookup for models from 10 to 19 SEER, which covers most Trane ACs and heat pumps currently in use. Here is our sample Trane XL16i model number: 4TTX6048J. The model number tells us that this is a 16 SEER AC, and its size is 48,000 BTU or 4 tons. On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics. Concentric Termination Kit. − Facilitates installation of combustion air intake pipe and flue exhaust pipe. − 1−1/2 inch (38 mm) kit LB49107CE (60G77) or 2 inch (51 mm) kit (33K97) contains concentric termination assembly, mounting clamp, roof flashing, reducer bushing and 45 degree elbow. − Kit requires single hole penetration of roof ...Instagram:https://instagram. ashley furniture orland parkloan nguyen pimple poppinguva academic calendar 2024 25forever love ep 5 eng sub Model No. Suction Evaporator LSA072C 89K83 93K76 LSA090C 79K90 93K77 LSA120C 89K84 93K78 FIELD INSTALLED Thermostat - Thermostat is not furnished with unit and must be ordered extra. - See Thermostats bulletin and Lennox Price Book. Hail Guard Protection - Heavy duty field installed coil guard protects coils from damage. - LSA072C uses (86K90). irmo fit body boot campkosher in crown heights (TXV) and RFC systems. Refer to Lennox engineering handbook for expansion valve kits which must be ordered separately. Shipping & Packing List 1 - Assembled HS29 condensing unit 1-45E copper street elbow 1 - RFCIV refrigerant metering orifice 1 - Coupling, 5/16 x 3/8" (012, 018, 024, 030) Check equipment for shipping damage. If you find any let's go luna funding credits Quality Parts & Supplies. LennoxPros has 1000s of HVAC Parts and Supplies from adapter curbs to welding equipment. Give LennoxPros.com a try or stop by a Lennox Store location near you. Shop Parts & Supplies. Find Lennox OEM repair parts fast. Our Repair Part Finder lets you search by model number, part number, serial number or catalog …For the layman, model numbers might look strange and weird. But still, every letter in the Trane furnace model number can signify something about the model. Decoding any equipment model number by standard means requires lots of valuable time. The Trane model number nomenclature is broken down into segments. Each segment will have a number of ...